HIGH   VOLTAGE   GENERATORS
15000 - 40000 W Series
From  300V to 200 kV  OUTPUT VOLTAGE
  Telonic Instruments Limited  
   
 
  • Voltage & Current Ouputs continuously adjustable from 0 to full scale
  • Low stored energy
  • High Efficiency
  • Total protection against arcs, overloads and short circuits
  • Customized V and C full scales* with no extracost
  • V & C Setting and Monitoring from front panel or REMOTE
  • High precision regulation
  • Remote, Inhibit & Interlock functions
  • High reliability
  • Compact design
  • Double Resonance Technology (ZVC)
  • Automatic crossover
  • Over Current Limitation and Protection functions
  • Polarity display
  • Safety switch key
  • Master-slaves architecture allowing to go beyond 40 kW
    *You can choose your own full scales (Vmax and Imax) even if
    these values are not available in standard. For example, you can
    get a 15 000 V generator based on 30 000 W model. In this case,
    you will get an Output Voltage adjustable from 0 to 15 000 V and
    an Output Current from 0 to 2 A.
     
 
  DESCRIPTION
  OPTIONS
 
 

Double Resonance Technology operating at high frequencies (50 kHz) offers a smooth switching to all the critical components and provides them a non-stressing behaviour. Internal power dissipation, harmonics & ripple are significantly reduced.

Hence, our generators can intensively operate with no failure even in rugged environments. Many of them are used at full power 24h/day, 7days/week with no failure for many years. Four series of power are offered from 15 kW to 40 kW.

Much higher powers can be reached by using a master/slave architecture. With its low cost per Watt, this series is particularly well adapted in applications looking for power and performance at competitive prices.

 
  • Other Voltage and Current values available with no extracost*
  • Reversibility and Floating outputs
  • 4 1⁄2 digit display
  • Non instrumented version
  • Power regulation
  • Arc Detection and counting
  • RS232, GPIB and PROFIBUS interfaces
  • Optic fibre transmission
  • LABVIEW driver
  • Relay interface
  • Customer Remote Adaptation
  • Single or multichannel control unit
  • Safety signs and devices alerting to Hazard
  • Tropicalization
  • Transportable “all terrain” container
  • Specific AC or DC main power inputs
  • OEM version
    Any Special requests can be considered
 
 
  ELECTRICAL SPECIFICATIONS
 
 
  • Output Voltage and Output Current:
    Both Voltage Output and Current Output are continuously
    adjustable from 0 to 100 % (full scale)
    In local mode: by using 10 turns potentiometers resolution
    0.05%
    In remote mode: by an external 0 to 10 V Voltage
  • Voltage regulation:
    Load Regulation: ± 0.05 % of full voltage (for 0 – 100 %
    load change); ± 0.01% available on request.
    Line Regulation: ± 0.05 % of full voltage ( for Main Voltage
    ± 10 %); ± 0.01% available on request.
  • Current regulation:
    Load Regulation: ± 0.05 % of full current (for 0 – 100 %
    load change)
    Line Regulation: ± 0.05 % of full current (for Main Voltage
    ± 10 %)
  • Ripple + Noise:
    0.1 % p-p
  • Setting Time:
    < 100 ms, 10 ms available on request.
 
  • Stability after one hour of warm-up:
    0.01 % / hour , 0.03 % / 8 hours of operating with constant
    load and ambiant temperature.
  • Temperature Coefficient:
    100 ppm/°C
  • Operating Temperature:
    from 0 to 40°C
  • Efficiency:
    > 92 % full load
  • Recovery Time After Arc:
    < 1 mS
  • Stored Energy:
    1J / kW
  • Cooling by air:
    Dust filter fans on front panel. Easily removable
    filters for cleaning.
  • Main Voltage:
    400 VAC ± 10 % 47 – 63 Hz 3 Phases + Earth
  • Power factor:
    > 0.98
  • Calibration:
    with probes periodically approved by Authorized Measurement Laboratories
  • CE Marking
 
 
  PHYSICAL DESCRIPTION
 
 
 
5U-19" Rack High Voltage Generator
7U-19" Rack High Voltage Generator
5U - 19” Rack
7U - 19” Rack
19” Cabinet
Dimensions
H 222 x W 483 x D 480 mm
H 311 x W 483 x D 600 mm
Height: from 12 to 30 HU
Depth: 600 mm or 800 mm
 
     
 
SR 5 kW Series
SR 6 kW Series
SR 8 kW Series
SR 10 kW Series
Voltage
A
Model
A
Model
A
Model
A
Model
300 V 50.00 SR0.3-X-12000 66.67 SR0.3-X-20000 100.00 SR0.3-X-30000 133.33 SR0.3-X-40000
700 V 21.43 SR0.7-X-12000 28.57 SR0.7-X-20000 42.86 SR0.7-X-30000 57.14 SR0.7-X-40000
1 KV 15.00 SR1-X-12000 20.00 SR1-X-20000 30.00 SR1-X-30000 40.00 SR1-X-40000
2.5 KV 6.00 SR2.5-X-12000 8.00 SR2.5-X-20000 12.00 SR2.5-X-30000 16.00 SR2.5-X-40000
5 KV 3.00 SR5-X-12000 4.00 SR5-X-20000 6.00 SR5-X-30000 8.00 SR5-X-40000
10 KV 1.50 SR10-X-12000 2.00 SR10-X-20000 3.00 SR10-X-30000 4.00 SR10-X-40000
15 KV 1.00 SR15-X-12000 1.33 SR15-X-20000 2.00 SR15-X-30000 2.67 SR15-X-40000
20 KV 0.75 SR20-X-12000 1.00 SR20-X-20000 1.50 SR20-X-30000 2.00 SR20-X-40000
30 KV 0.50 SR30-X-12000 0.67 SR30-X-20000 1.00 SR30-X-30000 1.33 SR30-X-40000
40 KV 0.38 SR40-X-12000 0.50 SR40-X-20000 0.75 SR40-X-30000 1.00 SR40-X-40000
50 KV 0.30 SR50-X-12000 0.40 SR50-X-20000 0.60 SR50-X-30000 0.80 SR50-X-40000
60 KV 0.25 SR60-X-12000 0.33 SR60-X-20000 0.50 SR60-X-30000 0.67 SR60-X-40000
80 KV 0.19 SR80-X-12000 0.25 SR80-X-20000 0.38 SR80-X-30000 0.50 SR80-X-40000
100 KV 0.15 SR100-X-12000 0.20 SR100-X-20000 0.30 SR100-X-30000 0.40 SR100-X-40000
120 KV 0.13 SR120-X-12000 0.17 SR120-X-20000 0.25 SR120-X-30000 0.33 SR120-X-40000
150 KV 0.10 SR150-X-12000 0.13 SR150-X-20000 0.20 SR150-X-30000 0.27 SR150-X-40000
Polarity : P - Positive, N - Negative, R - Reversible, F - Floating outputs                          Higher Voltages : Please contact us
Example of reference:
SR - 15 - R - 20000        
Model
SR model (Supply Regulation)
SR        
Voltage
Adjustable Voltage from 0 to 15 kVolts
15        
Polarity
Reversible polarity
R        
Power
20000 W Power
20000