Kikusui TOS5301 AC/DC Flash Tester / Hipot Tester 0-5kV(AC) 0-6kV(DC) AC 0-100mA (200mA S/C)/ DC 0-10mA

£2090.00 (£2,508.00 inc VAT)

5 in stock (can be backordered)

Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

SKU: TOS5301 Category:

Description


Kikusui TOS5301 Safety Tester

The Kikusui TOS5301 is a AC/DC withstanding voltage tester. It has an AC output of 5 kV/100 mA (200mA S/C 500VA Capacity)and DC 6kV 0-10mA, the TOS5301 can be used in Hipot/withstanding voltage testing of electronic equipment and electronic parts, based on the requirements of IEC, EN, UL, VDE, JIS, and other international safety standards. Also, the test voltage stability is improved with the adoption of a newly developed switching amplifier. Since the output voltage can be kept constant even when the AC line voltage or frequency changes, consistent testing can be performed, even when the power supply environment is in an unstable region. The TOS5300 is also equipped with a number of features. Rise time/Fall time control, Key lock function and Protection cover for key operation, Equipped with USB interface. Supplied with..
  • New Calibration Certificate (Traceable to National Standards)
  • Test Leads
  • Mains Lead
  • Operation Information
Features:
  • Reducing the tact time
  • Increasing the productivity!
  • Capable of setting the test time from 0.1s
  • Rise/Fall Time control function of the applied voltage
  • The utility software: Data Acquisition for TOS5300 (Freeware)
  • Also Availabe for Hire

Product Videos

Documentation

TOS5301/2 Specifications
Model TOS5301 TOS5302
AC Output Section
Output Range 0.05 kV to 5.00 kV 0.05 kV to 5.00 kV
Accuracy ±(2 % of set + 20 V) when no load is connected ±(2 % of set + 20 V) when no load is connected
Setting Range 0.00 kV to 5.50 kV 0.00 kV to 5.50 kV
Resolution 10 V steps 10 V steps
Max. rated output 500 VA (5 kV/100 mA) 500 VA (5 kV/100 mA)
Max. rated voltage 5 kV 5 kV
Max. rated current 100 mA (when the output voltage is 0.5 kV or greater) 100 mA (when the output voltage is 0.5 kV or greater)
Transformer rating 500 VA 500 VA
Output voltage waveform Sine Sine
Distortion If the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load is connected). If the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load is connected).
Frequency 50 Hz or 60 Hz 50 Hz or 60 Hz
Accuracy ±0.5 % (excluding during voltage rise time) ±0.5 % (excluding during voltage rise time)
Voltage regulation 10 % or less (when changing from maximum rated load to no load) 10 % or less (when changing from maximum rated load to no load)
Input voltage variation ±0.3 % (5 kV when no load is connected; power supply voltage: 90 V to 250 V) ±0.3 % (5 kV when no load is connected; power supply voltage: 90 V to 250 V)
Short-circuit current 200 mA or more (when the output voltage is 1.0 kV or greater) 200 mA or more (when the output voltage is 1.0 kV or greater)
Output method PWM switching PWM switching
DC Output Section
Output range 0.05 kV to 6.00 kV —–
Accuracy ±(2 % of set + 20 V) when no load is connected —–
Setting range 0.00 kV to 6.20 kV —–
Resolution 10 V steps —–
Max. rated output 50 W (5 kV/10 mA) —–
Max. rated voltage 6 kV —–
Max. rated current 10 mA —–
Ripple (TYP) 5 kV when no load is connected: 50 Vp-p
Max. Rated Load: 100 Vp-p
—–
Voltage regulation 3 % or less (when changing from maximum
rated load to no load)
—–
Short-circuit current (TYP) 40 mA (when generation 6 kV output) —–
Discharge feature Forced discharge after test completion
(discharge resistance: 125 kΩ)
—–
Start Voltage The voltage at the start of withstanding voltage tests can be set to 50% of the test voltage The voltage at the start of withstanding voltage tests can be set to 50% of the test voltage
Limit Voltage The test voltage upper limit can be set . AC: 0.00 kV to 5.50 kV, DC: 0.00 kV to 6.20 kV The test voltage upper limit can be set . AC: 0.00 kV to 5.50 kV, DC: 0.00 kV to 6.20 kV
Output voltage monitor feature If output voltage exceeds the specified value + 350 V or is lower than the specified value – 350 V,
output is turned off, and protective features are activated.
If output voltage exceeds the specified value + 350 V or is lower than the specified value – 350 V,
output is turned off, and protective features are activated.

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Mandatory Accessories …

  • UK Power Cord

    .
    Read more
  • Kikusui TL31-TOS High-Voltage Test Lead

    .
    Add to basket

Optional Accessories …

  • Kikusui PL02-TOS Warning Light

    £311.00
    Add to basket
  • Kikusui DD-5P/9P Conversion cable(DIN to Mini DIN)

    £42.00
    Add to basket
  • Kikusui TL31-TOS High-Voltage Test Lead

    £53.00
    Add to basket
  • Kikusui TL32-TOS High-Voltage Test Lead

    £68.00

    3 in stock (can be backordered)

    Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

    Add to basket
  • Kikusui RC01-TOS Remote Control Box

    £153.00
    Add to basket
  • Kikusui TU01-TOS Terminal Unit

    £222.00
    Add to basket
  • Kikusui HP02A-TOS High-Voltage Test Probe

    £271.00
    Add to basket
  • Kikusui HP01A-TOS High-Voltage Test Probe

    £256.00
    Add to basket
  • Kikusui RC02-TOS Remote Control Box

    £180.00
    Add to basket