Micsig CP503 High Frequency 30A AC DC 50MHz Current Probe

£435.00 (£522.00 inc VAT)

Available on back-order

Description


Micsig CP503 AC/DC 30A 50MHz Oscilloscope Probe for measuring direct and alternating current with a current of up to 30 A with a 50 MHz Bandwidth, it can be connected to the oscilloscope through the Micsig UPI connector. It does not require an external power supply.

Features:
  • Dual range selection, easy to measure low current
  • Degaussing and automatic Zero setting
  • Wide bandwidth with superior 1% accuracy (typical)
  • Directly powered by Micsig UPI interface (CP1003/CP503)

 

Model Bandwidth Rise Time Power Interface Range Output Sensitivity DC accuracy (typical)
CP503 50MHz ≤7ns Micsig UPI 6A(2X)/ 30A(10X) 1V/2A(6A ) 1V/10A(30A) ±1%±10mA(6A ) ±1%±50mA(30A)
CP1003 100MHz ≤3.5ns Micsig UPI 6A(2X)/ 30A(10X) 1V/2A(6A ) 1V/10A(30A) ±1%±10mA(6A ) ±1%±50mA(30A)
CP503B 50MHz ≤7ns Standard BNC 6A(2X)/ 30A(10X) 1V/2A(6A ) 1V/10A(30A) ±1%±10mA(6A ) ±1%±50mA(30A)
CP1003B 100MHz ≤3.5ns Standard BNC 6A(2X)/ 30A(10X) 1V/2A(6A ) 1V/10A(30A) ±1%±10mA(6A ) ±1%±50mA(30A)
 

Documentation


User Manual CP503/CP1003

Micsig CP503/CP1003 User Manual


Data Sheet CP503/CP1003

Micsig CP503/CP1003 Data Sheet



CP503 Specifications
Model CP503
Bandwidth 50MHz
Current range 6A (2X) / 30A (10X)
Output Connector Powered BNC / External BNC
Output Sensitivity 1V/2A (6A) 1V/10A (30A)
Typical Accuracy 1%
Phase Accuracy ≤0.8° (45Hz-66Hz)
Temperature Coefficient Operating temp. range + 0.05 × Accuracy Specification /℃ (23℃±5℃)
Conductor Positional Accuracy Within ±1% (Deviation from the Center)
Influence of External Magnetic Fields 1.5% f.s. or below (400A/m,50Hz/60Hz)
Offset Voltage ±1mV or below
Max Voltage CAT I 300V

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.