Kikusui PCR500LE (Three units required for 3 phase) is an extremely high quality programmable variable frequency AC power supply, Measurements include full line voltage simulation, apparent power, power factor, true power, Vrms, I rms , I peak, power W, frequency Hz, harmonic current measurement, Optional plug-in cards extend functionality. USB memory devices can store the data contained on the main unit memory, panel settings, power line abnormality simulations, and sequence data. Usable for systems to test conformance to the IEC61000-3 and 4 Series standards. Optional applications software also offered.
Product Videos
DCPS35V49V DCPS40A99A
- AC mode output (AC rms)
-
- PCR500LE
- PCR1000LE
- PCR2000LE
- PCR3000LE
- PCR4000LE
- PCR6000LE
- PCR9000LE
- Voltage (output L range, output H range)
- Rating
- 1 V to 150 V, 2 V to 300 V
- Setting range
- 0 V to 152.5 V, 0 V to 305.0 V
- Resolution
- 0.1 V
- Accuracy*1
- ±(0.3 % of set + 0.6 V)
- Max. current (output L range, output H range)*2
- 5 A, 2.5 A
- 10 A, 5 A
- 20 A, 10 A
- 30 A, 15 A
- 40 A, 20 A
- 60 A, 30 A
- 90 A, 45 A
- Phase
- Single-Phase
- Power capacity
- 500 VA
- 1 kVA
- 2 kVA
- 3 kVA
- 4 kVA
- 6 kVA
- 9 kVA
- Maximum peak current*3
- Maximum current (rms) x 4 (TYP)
- Maximum reverse current*4
- 30 % of the maximum current (rms)
- Load power factor
- 0 to 1 (leading or lagging)*2
- Frequency*2
- Setting range
- 1 Hz to 999.9 Hz*5
- Resolution
- 0.01 Hz (1.00 Hz to 100.0 Hz), 0.1 Hz (100.0 Hz to 999.9 Hz)
- Accuracy
- ±1 × 10-4
- *1. When the output frequency is between 45 Hz and 65 Hz, with no load, and at 23°C±5°C.
- *2. When the maximum voltage is between 1 V and 100 V (L range) or 2 V and 200 V (H range) and the load power factor is between 0.8 and 1.
- When the output voltage is between 100 V and 150 V (L range) or 200 V and 300 V (H range), the output current is reduced by the output voltage.
- When the load power factor is between 0 and 0.8, the output current is reduced by the load power factor.
- When the output frequency is between 1 Hz and 40 Hz, the output current is reduced by the output frequency.
- *3. For capacitor-input rectifier loads (however, this is limited by the rated output current’s rms value).
- *4. When the output voltage is 100 V or 200 V and the output frequency is between 40 Hz and 999.9 Hz (current is -90 deg to -180 deg/ 90 deg to 180 deg out of phase with the output voltage).
- *5. The frequency is limited to the range from 1 Hz to 500.0 Hz when the 3P05-PCR-LE(500HZ LMT) is installed in the PCR-LE series.
- TOP
- DC mode output
-
- PCR500LE
- PCR1000LE
- PCR2000LE
- PCR3000LE
- PCR4000LE
- PCR6000LE
- PCR9000LE
- Voltage (output L range, output H range)
- Rating
- -1.4 V to -212 V and +1.4 V to +212 V, -2.8 V to -424 V and -2.8 V to -424 V
- Setting range
- -215.5 V to +215.5 V, -431.0 V to +431.0 V
- Resolution
- 0.1 V
- accuracy*1
- ±(0.05 % of set + 0.05 V, 0.1 V)
- Maximum current*2
- 3.5 A, 1.75 A
- 7 A, 3.5 A
- 14 A, 7 A
- 21 A, 10.5 A
- 28 A, 14 A
- 42 A, 21 A
- 63 A, 31.5 A
- Maximum instantaneous current*3
- Maximum current (rms) × 3.6
- Power capacity
- 350 W
- 700 W
- 1.4 kW
- 2.1 kW
- 2.8 kW
- 4.2 kW
- 6.3 kW
- *1. With no load at 23°C±5°C.
- *2. When the output voltage is between 100 V and 212 V (L range), 200 V and 424 V (H range), the output current is reduced by the output voltage.
- *3. Limited by the rated output current's rms value.
- TOP
- AC + DC mode output
-
- Setting range
- Resolution
- Setting accuracy
- Voltage setting
- The AC voltage setting range is the same as the range in AC mode.
- The DC voltage setting range is the same as the range in DC mode.
- However, the peak AC+DC voltage must be within the DC voltage setting range.
- AC voltage setting + DC voltage setting
- Maximum current
- The same as the setting in DC mode
- Maximum instantaneous current
- Power capacity
- The same as the setting in DC mode
- Frequency
- The same as the setting in AC mode
- TOP
- Output voltage stability
-
- PCR500LE
- PCR1000LE
- PCR2000LE
- PCR3000LE
- PCR4000LE
- PCR6000LE
- PCR9000LE
- Line regulation*1
- Within ±0.1 %
- Load regulation (output L range, output H range)*2
- Within ±0.1 V, within ±0.2 V
- Output frequency variation*3
- Response: FAST
- Within ±0.2 %
- ---
- Response: MEDIUM
- Within ±0.3 %
- Ripple noise in DC mode (5 Hz to 1 MHz components)
- 0.15 Vrms or less
- 0.2 Vrms or less
- 0.25 Vrms or less
- Ambient temperature variation*4
- ±100 ppm/°C(TYP)
- *1. With respect to changes in the rated range of input voltage.
- *2. With respect to 0 % to 100 % changes in the ratingof output current.
- When the output voltage is between 80 V and 150 V (L range) or 160 V and 300 V (H range) and the load power factor is 1. At the output terminal block. When the response mode is set to FAST or MEDIUM.
- *3. Between 40 Hz and 999.9 Hz.
- When the output voltage is between 80 V and 150 V (L range) or 160 V and 300 V (H range) and the load power factor is 1. This is the output line regulation with 200 Hz as the reference.
- *4. With respect to changes in the operating temperature range.
- When the output voltage range is 100 V or 200 V and the output current is 0 A.
- TOP
- Output frequency stability, output voltage waveform distortion ratio, output voltage response speed, efficiency
-
- PCR500LE
- PCR1000LE
- PCR2000LE
- PCR3000LE
- PCR4000LE
- PCR6000LE
- PCR9000LE
- Output frequency stability*1
- Within ±5×10-5
- Output voltage waveform distortion ratio*2
- Response: FAST
- 0.2 % or less
- ---
- Response: MEDIUM
- 0.3 % or less
- Output voltage response speed*3
- Response: FAST
- 20 µs(TYP)
- ---
- Response: MEDIUM
- 30 µs(TYP)
- Efficiency
- 54 % or more, 56 % or more*4
- 55 % or more, 57 % or more*4
- 58 % or more*5
- *1. For changes within the rated ranges of all specifications
- *2. When the output voltage is between 80 V and 150 V (L range) or 160 V and 300 V (H range) and the load power factor is 1.
- *3. When the output voltage is 100 V or 200 V, the load power factor is 1, and the output current changes from 0 A to the rated value and from the rated value to 0 A.
- *4. When the input voltage is 100 V or 200 V, the output voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 999.9 Hz.
- *5. When the input voltage is 200 V, the output voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 999.9 Hz.
- TOP
- Meters (fluorescent display)
-
- PCR500LE
- PCR1000LE
- PCR2000LE
- PCR3000LE
- PCR4000LE
- PCR6000LE
- PCR9000LE
- Voltmeter*1
- Resolution
- 0.1 V
- Accuracy*2
- ±(1 % of reading +2 digits)
- Ammeter*1
- Resolution
- 0.01 A
- 0.1 A
- Accuracy*3
- ±(1 % of reading +2 digits)
- Wattmeter*4
- Resolution
- 0.1 W, 1 W
- 1 W
- Accuracy*5
- ±(1 % of reading +3 digits)
- Frequencymeter*6
- Resolution
- 0.01 Hz (1.00 Hz to 99.99 Hz), 0.1 Hz (100.0 Hz to 999.9 Hz)
- *1. With the true rms display, a waveform with a crest factor of 3 or less, DC, output frequency between 40 Hz and 999.9 Hz, RMS, and AVE.
- *2. 10 V to 424 V and at 23°C±5°C.
- *3. 5 % of the max. rated current to max. rated current and at 23°C±5°C.
- *4. When the output frequency is between 45 Hz and 65 Hz.
- *5. 10 % of the rated power capacity to the rated power capacity, when the load power factor is 1, and at room temperature.
- *6. Displays the output frequency setting (frequency of the internal reference voltage).
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- High-quality/high-stability output using high-speed linear amplifier
- Capable of various power line abnormality simulations and sequenced programmed operation
- Single phase 500 VA, expandable with optional drivers for single-phase three-wire, and three-phase operation
- Features a full range of measuring functions and supports AC, DC, and AC + DC Outputs
- Variable output impedance
- Power Line Disturbance Immunity Testing Software
- Sequence Creation Software - program sequences of outputs required
- Avionics test software - supports standards MIL-STD-704, RTCA/D0-160 and JIS W0812
- Line Impedance Network option
- IEC DIP simulator (fast voltage dips 1uS to 5uS)
- Measurement of harmonic current
- Soft-start capability for sensitive loads/testing
- Optional plug-in boards: GPIB, USB, Ethernet, external signal input (PCR unit acts as an amplifier), remote control of output (using DC control input), 3 phase boards for interconnection between PCR-LE units
- Detachable front panel
- Eco-friendly function equipped
- RS232 fitted as standard
- Dimensions (mm) 430W x 195H x 600D 17Kg
- (See also PCR1000LE, PCR2000LE etc for higher power output up to 54kVA single phase, 81kVA three phase)
|
|
 |
 |
 |
 |


|