TOS5200 0-5kV AC Flash Tester features 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by the AC power line. Therefore, it is a perfect solution for safety testing electronic equipment or devices complied to IEC, EN, UL, VDE and JIS etc. requirements. As TOS5200 covers most of features of our advanced model for AC Hipot Test, it has a superb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also comes equipped the Interlock function together with other safety features.
Supplied with.. New Calibration Certificate (Traceable to National Standards) Test Leads Mains Lead Operation Information.
Specification- Unless otherwise specified, the specifications are for the following settings and conditions.
- • Warm-up time is 30 minutes.
- • TYP value: typical value. We do not guarantee the performance.
- • rdng: shows the readings.
- • set: Represents a set value.
- • fs: full scale
- * 1. For the time limit for the output
- heat transfer capability of the withstand voltage voltage generator, the size, weight, in consideration of the cost, has become a half of the design of the rated output.
- Please use it within the following limits. When used with the restriction outside, the temperature of the output unit is over-rise, there are times when the internal protection circuit is activated.
- Please wait until it returns to normal temperature to interrupt the test at that time.
-
- Ambient temperature
-
| -
- Upper limit reference value
-
| -
- Down time
-
| -
- Output time
-
| -
- t ≦ 40 ℃
-
| -
- AC
-
| -
- 50mA <i
-
| -
- Output time equal to or greater than
-
| -
- Up to 30 minutes
-
| -
- i ≦ 50 mA
-
| -
- Unnecessary
-
| -
- Continuous output possible (up to 24H)
-
|
- (Output time = voltage rise time + test time + voltage fall time) * 2. For the test voltage waveform if you have to load a sample (such as a ceramic capacitor) the value of the capacity of voltage dependence, waveform distortion occurs You may. However, if the test voltage of 1.5 kV, the effect of the following capacity 1000 pF can be ignored. High voltage power supply unit of this product because of the PWM switching method, switching noise in the test voltage is 500 V or less, the proportion of the spike noise increases, waveform distortion also increases as the test voltage is lower. * 3. True RMS value, in any of the average value is also to meet the measurement accuracy is required response time of more than 50ms. * 4. Current meter accuracy, the determination accuracy in AC withstanding voltage test, the voltage also flows into the stray capacity of measurement leadwire and jigs. Current flowing into the stray capacitance, is measured are added to the current flowing through the UUT. In particular, high sensitivity, in the case where the judgment of the high-precision, care must be taken, such as adding the current flowing into the stray capacity to upper / lower reference value.
-
- Output voltage
-
| -
- 1 kV
-
| -
- 2 kV
-
| -
- 5 kV
-
| -
- When hanging air the lead of length 350 mm (TYP value)
-
| -
- 2 μA
-
| -
- 4 μA
-
| -
- 10 μA
-
| -
- High voltage test leads TL31-TOS when using the supplied (TYP value)
-
| -
- 16 μA
-
| -
- 32 μA
-
| -
- 80 μA
-
|
- In the case of a humidity of 70% or more, adds the 50μA.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- High stability.
- 5kV / 100mA (500VA) AC withstand Voltage
- High-precision measurement ± 1.5% of reading
- Rise time / fall time control
- Key lock & operation cover
- USB, RS-232C interface equipped
|
|
 |
 |
 |
 |


|