Kikusui TOS9303LC AC/DC Hipot Tester with Insulation Resistance, Ground Bond and Leakage Current Test Rental

£350.00 (£420.00 inc VAT)

RENTAL PRICE PER WEEK

1 in stock (can be backordered)

Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

Description


Kikusui TOS9303LC Safety Tester Rental

The TOS9300 Series is a high performance electrical safety analyser that complies to a wide range of universal standards. HiPot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests. The TOS9300 Series is a high performance electrical safety analyser that complies to a wide range of universal standards. HiPot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests. Features:
  • User-friendly 10Key configuration
  • Easy firmware updates via USB
  • LAN/USB/RS232C Standard Digital Interface
  • I/V Monitor Terminal (Analog Monitor)
  • STATUS OUT Connector
  • SIGNAL I/O Connector
  • High Precision/High Resolution/High Speed
  • Programmable detection response speed
  • 7.2kV/100W DC HiPot Test
  • Positive Electrode/Negative Electrode Insulation Resistance Testing
  • Electric Discharge Function
  • AC/DC Earth Continuity testing up to 40A
  • EARTH FAULT Protection
  • Offset Cancel
  • Basic memory function
  • Calibration deadline notification
  • High-voltage scanner (option)
Specification:
  • Max output-voltage of AC HiPot testing: 5kV / 100mA(500VA)
  • Max output-voltage of DC HiPot testing: 5kV / 20mA, 7.2kV.13.9mA(100W)
  • Measurement range insulation resistance testing: 0.001MΩ to 100.0GΩ (DC -25V to -1000V / DC +50V to +7200V)
  • Measurement range of ground boMend testing: 0.001Ω to 0.600Ω (3.0A to 42.0A)
  • Measurement range of leakage current testing: 1μA to 100mA(rms)
  • Rise-time control / fall-time control function provided
  • Output voltage and panel settings are controlled through LAN/USB/RS232C
 

Product Videos

Documentation

TOS9300 Specifications
Model TOS9300 TOS9301 TOS9302 TOS9303 TOS9303LC
Output Function
AC Output Section
Output range 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV
Resolution 1 V 1 V 1 V 1 V 1 V
Setting accuracy ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load)
Max. rated load 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA)
Max. rated current 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher)
Transformer rating 500 VA 500 VA 500 VA 500 VA 500 VA
Output voltage waveform Sine Sine Sine Sine Sine
Distortion 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected)
Crest factor √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more)
Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz
Accuracy ±0.1 % ±0.1 % ±0.1 % ±0.1 % ±0.1 %
Voltage regulation ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load)
Short-circuit current 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher)
Output method PWM switching PWM switching PWM switching PWM switching PWM switching
Start voltage The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set.
Setting range 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage
Resolution 1 % 1 % 1 % 1 % 1 %
Output voltage monitor function If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated.
DC Output Function
DC Output Section
Output voltage range 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV
Resolution 1 V 1 V 1 V 1 V 1 V
Setting accuracy ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V)
Max. rated load 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA)
Max. rated current 20 mA 20 mA 20 mA 20 mA 20 mA
Ripple
7.2 kV no load 20 Vp-p (TYP) 20 Vp-p (TYP) 20 Vp-p (TYP) 20 Vp-p (TYP) 20 Vp-p (TYP)
Max. rated load 50 Vp-p (TYP) 50 Vp-p (TYP) 50 Vp-p (TYP) 50 Vp-p (TYP) 50 Vp-p (TYP)
Voltage regulation 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load)
Short-circuit current 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak)
Discharge function Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ)
Start voltage The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set.
Setting range 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage
Resolution 1 % 1 % 1 % 1 % 1 %
Output voltage monitor function If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated.
Measurement Function
Voltmeter
Measurement range 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC
Resolution 0.1 V 0.1 V 0.1 V 0.1 V 0.1 V
Accuracy ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V)
Response Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Hold function The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed
Ammeter
Measurement range AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component)
Accuracy ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component)
Response Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion.
Hold function The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed
Offset cancel function Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Calibration Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Optional Accessories …

  • Kikusui PL02-TOS Warning Light

    £311.00
    Add to basket
  • Kikusui HP02A-TOS High-Voltage Test Probe

    £271.00
    Add to basket
  • Kikusui DD-5P/9P Conversion cable(DIN to Mini DIN)

    £42.00
    Add to basket
  • Kikusui HP01A-TOS High-Voltage Test Probe

    £256.00
    Add to basket
  • Kikusui OT01-TOS Multi-Output

    £385.00
    Add to basket
  • Kikusui TOS9320 High-voltage scanner

    £2,130.00
    Add to basket
  • Kikusui RC01-TOS Remote Control Box

    £153.00
    Add to basket
  • Kikusui RC02-TOS Remote Control Box

    £180.00
    Add to basket