The Rigol DSA800 series of spectrum analysers are small, light weight, easy to use and great value for money. The performance and features of these instruments, including the high definition colour LCD display and various remote communication interfaces, make these spectrum analysers highly versatile - Ideal for various environments such as R&D laboratories, education and manufacturing. Buy a DSA800 series spectrum analyser along with one of the EMC Near-Field Probe Sets from TekBox (see 'Accessories') and you'll have a valuable tool for EMC pre-compliance tests - Potentially saving a small fortune and project delays due to re-tests at an EMC Test House. Choose a Rigol DSA800 spectrum analyser with built-in tracking generator and you'll have the capability of making (forward and reverse) transmission measurements. Add a Rigol VSWR Bridge and you'd have the additional capability of measuring input or output return loss. The Rigol DSA800 series spectrum analysers have several other options available to enhance the capability and user experience even further. Whatever configuration you choose, we think that you'll be impressed by the value for money.
Click image to enlarge
-
-
| -
-
| -
-
| -
-
| -
-
| -
- Model
-
| -
- DSA815
-
DSA815-TG -
| -
- DSA832
-
DSA832-TG -
| -
- DSA875
-
DSA875-TG -
| -
- Frequency
-
| -
- Range
-
| -
- 9kHz - 1.5GHz
-
| -
- 9kHz - 3.2GHz
-
| -
- 9kHz - 7.5GHz
-
| -
- Resolution
-
| -
- 1Hz
-
| -
- Resolution Bandwidth (Note 1)
-
| -
- 100Hz to 1MHz, in 1-3-10 sequence
-
| -
- 10Hz to 1MHz, in 1-3-10 sequence
-
| -
- Video Bandwidth
-
| -
- 1Hz to 3MHz, in 1-3-10 sequence
-
| -
- Maximum Input Level
-
| -
- CW RF Power (Note 2)
-
| -
- 20dBm (100mW)
-
| -
- Damage Level (Note 3)
-
| -
- 30dBm (1W)
-
| -
- DC Voltage
-
| -
- 50V
-
| -
- Input Attenuator
-
| -
- 0dB to 30dB in 1dB steps
-
| -
- Preamplifier Gain
-
| -
- 20dB nominal
-
| -
- 17dB nominal (Optional)
-
| -
- Absolute Amplitude Uncertainty (Note 4)
-
| -
- <0.4dB
-
| -
- <0.3dB
-
| -
- Level Measurement Uncertainty (Note 5)
-
| -
- <1.5dB nominal
-
| -
- <0.8dB nominal
-
| -
- SSB Phase Noise (Note 6)
-
| -
- @ 10kHz
-
| -
- <-80dBc/Hz
-
| -
- <-98dBc/Hz
-
| -
- @ 100kHz
-
| -
- <-100dBc/Hz typ.
-
| -
- <-100dBc/Hz typ.
-
| -
- @ 1MHz
-
| -
- <-115dBc/Hz typ.
-
| -
- <-120dBc/Hz typ.
-
| -
- Displayed Average Noise Level, DANL (Note 7)
-
| -
- PA Off
-
| -
- <-130dBm/Hz, <-135dBm/Hz typ.
-
100kHz to 1.5GHz -
| -
- <-135dBm/Hz, <-138dBm/Hz typ.
-
100kHz to 5MHz -
<-140dBm/Hz, <-144dBm/Hz typ. -
5MHz to 3.2GHz -
| -
- <-140dBm/Hz, <-144dBm/Hz typ.
-
5MHz to 3.2GHz -
<-136dBm/Hz, <-140dBm/Hz typ. -
3.2GHz to 6GHz -
<-131dBm/Hz, <-135dBm/Hz typ. -
6GHz to 7.5GHz -
| -
- PA On (Note 8)
-
| -
- <-150dBm/Hz, <-155dBm/Hz typ.
-
100kHz to 1.5GHz -
| -
- <-152dBm/Hz, <-155dBm/Hz typ.
-
100kHz to 5MHz -
<-157dBm/Hz, <-161dBm/Hz typ. -
5MHz to 3.2GHz -
| -
- <-157dBm/Hz, <-161dBm/Hz typ.
-
5MHz to 3.2GHz -
<-153dBm/Hz, <-157dBm/Hz typ. -
3.2GHz to 6GHz -
<-148dBm/Hz, <-152dBm/Hz typ. -
6GHz to 7.5GHz -
| -
- Display - Level Axis
-
| -
- Logarithmic Scale
-
| -
- 1dB to 200dB
-
| -
- Linear Scale
-
| -
- 0 to Reference Level
-
| -
- Number of Display Points
-
| -
- 601
-
| -
- Number of Traces
-
| -
- 3 + Math Trace
-
| -
- Trace Detectors
-
| -
- Normal, Positive-Peak, Negative-Peak, Sample, RMS,
-
Voltage Average, Quasi-Peak (with EMI-DSA800 option) -
| -
- Trace Functions
-
| -
- Clear Write, Max Hold, Min Hold, Average, View, Blank
-
| -
- Units
-
| -
- dBm, dBmV, dBμV, nV, μV, mV, V, nW, μW, mW, W
-
| -
- Dimensions (W x H x D)
-
| -
- 362mm x 179mm x 128mm
-
| -
- Weight
-
| -
- 4.25kg
-
| -
- 4.55kg without tracking generator
-
5.15kg with tracking generator -
| -
- Tracking Generator
-
| -
- Model
-
| -
- DSA815-TG Only
-
| -
- DSA832-TG Only
-
| -
- DSA875-TG Only
-
| -
- Frequency Range
-
| -
- 100kHz to 1.5GHz
-
| -
- 100kHz to 3.2GHz
-
| -
- 100kHz to 7.5GHz
-
| -
- Output Level Range
-
| -
- -20dBm to 0dBm
-
| -
- -30dBm to 0dBm
-
| -
- Output Level Resolution
-
| -
- 1dB
-
|
Note 1: -3dB bandwidth, RBW Uncertainty <5% nominal, RBW Shape Factor (60dB:30dB) <5 nominal Note 2: Attenuation = 30dB Note 3: When fc≥10MHz, input level > 25dBm and PA is off, the protection switch will be on Note 4: fc = 50MHz, Peak Detector, PA Off, Attenuation = 10dB, Input Signal Level = -10dBm, 20⁰C to 30⁰C Note 5: 95% confidence level, S/N >20dB, RBW = VBW = 1kHz, preamplifier off, 10dB RF attenuation, -50dBm < RF ≤ 0dBm, fc >10MHz, 20⁰C to 30⁰C Note 6: 20⁰C to 30⁰C, fc = 1GHz Note 7: 0dB RF Attenuation, RBW = VBW = 100Hz, sample detector, trace average ≥50, 20⁰C to 30⁰C, input terminated 50Ω Note 8: A PA is optional on the following models: DSA832, DSA832-TG, DSA875, DSA875-TG
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- Frequency range from 9kHz to 7.5GHz
- Displayed average noise level (DANL) <-161dBm/Hz typ. (5MHz < f < 3.2GHz) with optional preamplifier on
- Minimum resolution bandwidth (RBW) 10Hz
- Phase noise <-98dBc/Hz @10kHz offset
- Level measurement uncertainty <0.8dB
- AM/FM demodulation function
- 8" (800 x 480) high-definition display
- Connectivity: LAN(LXI), USB Host & Device
- PictBridge support
- Compact size and light weight
- Supplied With... USB cable, UK & European mains leads, quick guide, CD (user guide & programming guide)
- Optional Ultra Spectrum PC software... Remote control, data storage & processing, various additional functions (e.g. 3-D display)
- Other options include... Built-in preamplifier, EMI filter & quasi-peak detector, advanced measurement functions, USB to GPIB module, rack mount kit, soft carry bag, RF transmitter demo kit, RF receiver demo kit, RCL standard calibration
|
|
 |
 |
 |
 |


|