RIGOL’s new MSO2202A 200MHz 2GSa/s 2 channel digital oscilloscope with built-in logic analyser offers a lower noise floor (vertical scale down to 500μ/div), selectable 50Ω input impedance and record/playback/analysis all as standard. Other standard features include a waveform capture rate up to 50,000wfms/s and a 8" WVGA display with 256 intensity level grading. The MSO2202A enables engineers to capture lengthy signal streams whilst retaining outstanding t-axis resolution.
Click image to enlarge
-
-
| -
-
| -
-
| -
-
| -
-
| -
- Model
-
| -
- MSO2072A
-
MSO2072A-S -
| -
- MSO2102A
-
MSO2102A-S -
| -
- MSO2202A
-
MSO2202A-S -
| -
- MSO2302A
-
MSO2302A-S -
| -
- Bandwidth
-
| -
- 70MHz
-
| -
- 100MHz
-
| -
- 200MHz
-
| -
- 300MHz
-
| -
- Channels
-
| -
- Analogue: 2
-
Digital: 16 -
| -
- Maximum Sample Rate
-
| -
- Analogue: 2GSa/s (1 channel), 1GSa/s (2 channels)
-
Digital: 1GSa/s (8 channels), 500MSa/s (16 channels) -
| -
- Maximum Memory Depth
-
| -
- Analogue: 14Mpts (56Mpts Optional)
-
Digital: 14Mpts (28Mpts Optional) -
| -
- Maximum Waveform Capture Rate
-
| -
- 50,000wfms/s
-
| -
- Time-Base Accuracy
-
| -
- ≤±25ppm
-
| -
- Time-Base Drift
-
| -
- ≤±5ppm/year
-
| -
- Time-Base Scale
-
| -
- 5ns/div to 50s/div
-
| -
- 2ns/div to 1,000s/div
-
| -
- 1ns/div to 1,000s/div
-
| -
- Input Impedance
-
| -
- 1MΩ ± 1% // 16pF ± 3pF or 50Ω ± 1.5%
-
| -
- Vertical Scale
-
| -
- Analogue: 500μV/div to 10V/div (1MΩ), 500μV/div to 1V/div (50Ω)
-
Digital: User Defined Threshold Range ±20V in 10mV Steps -
| -
- DC Gain Accuracy
-
| -
- ±2% Full Scale
-
| -
- Bandwidth Limit
-
| -
- 20MHz
-
| -
- 20MHz / 100MHz
-
| -
- Real Time Waveform Record,
-
Replay and Analysis Function -
| -
- Up to 65,000 Frames
-
| -
- Standard Trigger Functions
-
| -
- Edge, Pulse Width, Slope, Video, Pattern, Setup/Hold, RS232, I2C, SPI
-
| -
- Optional Trigger Functions
-
| -
- Windows, Nth Edge, HDTV, Delay, Time Out, Duration, USB, CAN
-
| -
- Standard Bus Decoding
-
| -
- Parallel Bus
-
| -
- Optional Bus Decoding
-
| -
- RS232, I2C, SPI, CAN
-
| -
- Math Functions
-
| -
- A+B, A-B, AxB, A/B, FFT, Advanced Math, Logic Operations
-
| -
- Auto Measurements
-
| -
- Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Area, Period Area,
-
Freq, Period, Rise Time, Fall Time, Width, -Width, Duty, -Duty, Delay A→B Rising Edge, -
Delay A→B Falling Edge, Phase A→B Rising Edge, Phase A→B Falling Edge -
| -
- Connectivity
-
| -
- USB Host & Device, LAN(LXI), Aux Output (TrigOut, PassFail)
-
Support USB-GPIB (Optional) -
| -
- Display
-
| -
- 8" WVGA (800x480) TFT LCD, 256 Intensity Grading Level
-
| -
- Size (WxHxD)
-
| -
- 361.6mm x 179.6mm x 130.8mm
-
| -
- Weight
-
| -
- 3.9kg ± 0.2kg (without package)
-
| -
- Standard Probes
-
| -
- RP3300A 350MHz BW Passive Probe: 2 sets + 1 set RPL2316 LA Probe
-
| -
- Built-In 2 Channel Waveform Generator
-
| -
- MSO2XX2-S Models Only
-
2 Channels -
200MSa/s Sample Rate -
14bits Vertical Resolution -
25MHz Maximum Output Frequency -
20mVpp - 5Vpp Amplitude Range (High Z) -
16kpts Waveform Length -
Standard Waveforms - Sine, Square, Ramp, Pulse, Noise, DC -
Arbitrary Waveforms - Sinc, ExpRise, ExpFall, ECG, Gauss, Lorentz, Haversine, User Defined -
|
|
|
|
|
To download Rigol Ultra Sigma PC software...
CLICK HERE
|
|
Rigol Ultra Sigma Overview
|
To download Rigol Ultra Power Analyser PC software...
CLICK HERE
|
Please note...
1. The software files must be extracted before installation.
2. Ultra Sigma must be installed before any other Rigol application.
3. To open Ultra Power Analyser - Open Ultra Sigma, then connect your instrument, then open Ultra Power Analyser from within Ultra Sigma.
4. .CHM files must be 'unblocked' (from within the file 'Properties' window) before use.
|
|
Rigol MSO/DS2000A Series Datasheet
|
|
Rigol MSO/DS2000A Series User Guide
|
|
Rigol MSO/DS2000A Series Programming Guide
|
|
|
Deep Memory Advantage
|
|
Abnormal Signal Capture
|
|
Advanced Maths Functions
|
|
FFT Function Example
|
|
Waveform Record Function
|
|
Recording Specific Frames
|
|
PassFail Function
|
|
Measuring Narrow Pulses
|
|
Pulse Trigger Function
|
|
Runt Trigger Function
|
|
Video Trigger Function
|
|
Nth Edge Trigger Function
|
|
Windows Trigger Function
|
|
Slope Trigger Function
|
|
Duration Trigger Function
|
|
TimeOut Trigger Function
|
|
RS232 Bus Analysis
|
|
I2C Bus Analysis
|
|
CAN Bus Analysis
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
-
- 200MHz bandwidth, 2 channel digital oscilloscope with built-in logic analyser
-
- Maximum sample rate 2GSa/s
-
- Vertical scale 500μV/div to 10V/div
-
- Selectable 50Ω input impedance
-
- Memory depth up to 14Mpts (56Mpts optional)
-
- Innovative "UltraVision" technology
-
- Up to 50,000wfms/s waveform capture rate
-
- Up to 65,000 frames real-time waveform record, replay & analysis functions
-
- 8" WVGA (800x480) TFT LCD display, 256 intensity grading levels
-
- Up to 17-off trigger functions, including various protocol triggers
-
- Auto measurement of 29 waveform parameters, with statistics
-
- Built-in FFT with a choice of window functions
-
- Pass/fail test function
-
- Various waveform math functions
-
- Supports internal and external storage of instrument settings, waveforms, screen images and parameters
-
- PictBridge printer support
-
- Built-in help facility
-
- Connectivity: USB Host & Device, LAN(LXI), AUX Output, (USB-GPIB, optional)
-
- Supplied with... 2-off passive probes (350MHz), 1-off logic analyser probe set, USB cable, UK & European mains leads, quick guide, CD (user guide & application software)
-
- Options include... Deeper memory, advanced trigger functions, RS232/I2C/SPI decoding kit, CAN analysis kit, rack mount kit, soft carry bag, RCL standard calibration, RCL UKAS calibration
|
|
 |
 |
 |
 |


|